Orion showing hardware detailss incorrect reading of Critical for Cisco 3750x power stack.
![Up Up](http://orion/Orion/APM/Images/HardwareHealth/PowerSupply_Up.png)
Sw1, PS2 Faulty, RPS NotExistNot Functioning
Sw2, PS1 Normal, RPS NotExistNormal
Sw3, PS1 Faulty, RPS NotExistNot Functioning
Sw4, PS1 Normal, RPS NotExistNormal
But when I do a show stack power detail command everything show correctly
D1-3750x-01#sho stack-power detail
Power Stack Stack Stack Total Rsvd Alloc Unused Num Num
Name Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS
-------------------- ------ ------- ------ ------ ------ ------ --- ---
Powerstack-1 SP-PS Ring 2860 43 716 2101 3 4
Power stack name: Powerstack-1
Stack mode: Power sharing
Stack topology: Ring
Switch 1:
Power budget: 943
Power allocated: 223
Low port priority value: 20
High port priority value: 11
Switch priority value: 2
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 3 - 6c20.56a0.fa80
Neighbor on port 2: Switch 2 - 6c20.5695.1500
Switch 3:
Power budget: 961
Power allocated: 270
Low port priority value: 22
High port priority value: 13
Switch priority value: 4
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 2 - 6c20.5695.1500
Neighbor on port 2: Switch 1 - 6c20.5655.e700
Switch 2:
Power budget: 913
Power allocated: 223
Low port priority value: 21
High port priority value: 12
Switch priority value: 3
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 1 - 6c20.5655.e700
Neighbor on port 2: Switch 3 - 6c20.56a0.fa80
On a switch configured identical to one above
![Up Up](http://orion/Orion/APM/Images/HardwareHealth/PowerSupply_Up.png)
Sw1, PS2 Normal, RPS NotExistNormal
Sw2, PS1 Normal, RPS NotExistNormal
Sw3, PS1 Normal, RPS NotExistNormal
D1-3750x-02#sho stack-power detail
Power Stack Stack Stack Total Rsvd Alloc Unused Num Num
Name Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS
-------------------- ------ ------- ------ ------ ------ ------ --- ---
Powerstack-2 SP-PS Ring 2860 31 1071 1758 3 4
Power stack name: Powerstack-2
Stack mode: Power sharing
Stack topology: Ring
Switch 1:
Power budget: 943
Power allocated: 239
Low port priority value: 22
High port priority value: 13
Switch priority value: 4
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 3 - 6c20.5657.5100
Neighbor on port 2: Switch 2 - 6c20.5615.d300
Switch 2:
Power budget: 943
Power allocated: 393
Low port priority value: 20
High port priority value: 11
Switch priority value: 2
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 1 - 6c20.5695.1d80
Neighbor on port 2: Switch 3 - 6c20.5657.5100
Switch 3:
Power budget: 943
Power allocated: 439
Low port priority value: 21
High port priority value: 12
Switch priority value: 3
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 2 - 6c20.5615.d300
Neighbor on port 2: Switch 1 - 6c20.5695.1d80r statu..